Thermo King Athenia AM II 700

Call for Price

Call for Price

Overview

Availability Brochure
MakeThermo King
ModelAthenia AM II 700

Product Features

Description

For articulated trailers and 29’-32’ buses



A complete range of low-weight, high-performance roofmount HVAC systems for coach and transit applications. Featuring an updated design that delivers improved quality and reliability while offering new features and significant enhancements.

System Cooling Capacity
  • BTU/hr: 76,000
  • kW: 22.3 kW
  • Kcal/hr: 19,151
  • Rated Capacities are at the following conditions: Outside: 35°C/95°F; Inside: 27°C/80°F DB, 19°C/67°F WB
System Heating Capacity
  • At 30 Lt./Min.(8 GPM) coolant flow rate and 55K (100°F) temperature differential between return air and coolant.
  • BTU/hr: 90,000
  • kW: 26.4
  • Kcal/hr: 22.7
Evaporator Airflow
  • (0 in. water column external static pressure)
  • High Speed: 2150 ft3/min
  • Medium Speed: 1266 ft3/min
  • Low Speed: 900 ft3/min
Refrigerant
  • HFC R-134A
Power Consumption @ 27 VDC
  • 75.2 Amps
Weight
  • 435 lbs (197 kg)
Compressor Weight with Clutch (approximate)
  • S391: 147 lbs (67 kg)
  • S616: 171 lbs (77 kg)
  • X426/X430: 115 lbs (52.2 kg)
Delivers Quality & Reliability
  • 10% weight reduction
  • Welded frame
  • Reduced number of potential leak points
  • No sealants used in design
  • Stiffer construction for improved unit/bus sealing
  • 10% more condenser airflow
  • 5% more evaporator airflow
  • Access all servicable items from inside bus
  • Easy-to-install one-piece design
  • IntelligAIRE® III microprocessor controller with CANBUS communications
  • Designed to fit CNG, hybrid and diesel buses
One Platform for All Your Needs
  • Water Tight Design: Harness interface points use water-tight sealed fittings; No water ingress due to high/low pressure differentials; One piece welded frame; No rivets or sealant
  • New Side-Access Covers: Gull wing doors eliminate prop rods; Improved latching, sealing, access, and aesthetics
  • Unit Controls in Conditioned Air Space: Improved environmental protection; Improved access and serviceability
  • New Motorized Water Valve: Improved temperature control in re-heat and heating modes; Eliminates water hammer
  • New Electronic Capacity Control: Capacity can be reduced when not needed for fuel savings on cooler days; Improved temperature balance on Arctic buses so capacity can be shifted from unit to unit as needed
More Standard Features Than Ever
  • IntelligAIRE® III Control System: Expanded CAN communications capability; Plugs directly into J1939 network to make more info available; Eliminates the gateway module required between bus & unit controller; Eliminates the need for expansion modules external to the controller where multiple zones must be controlled independently
  • High-Performance R-407C or R-134A: Environmentally safe alternatives with zero ODP
  • The Thermo King X430 Compressor: Engineered exclusively for transport applications; Built for extended service life; Field repairable

Capacities

Cooling Capacity 76,000 BTU/hr (22.3 kW)
Heating Capacity 90,000 BTU/hr (26.4 kW)

Airflow

Airflow Volume High Speed: 2150 ft3/min

General

Weight 435 lb. (197 kg)

Shopping Tools